Profeq FAQ

FOUTMELDINGEN - Display elektrische zit-sta combinaties - TC15S, TC15P & TC16P

Error codes - TC15S, TC15P & TC16P

Reset Procedure:

Press up- & down button at the same time untill the frame has reached the lowest position. A beep will sound when the reset process is complete and the up- & down buttons can be released.

Error code Number of beeps Protection Situation Solution
E00 No beep Reset not fully performed The reset procedure is not fully completed. (if desk is 100 mm from the lowest position or less, the desk cannot synchronise during reset) 1) Make sure the frame is completely reset.
E01 3 beeps, 3 beeps when operating, until the desk is completely recoverd Overuse protection Moving the frame for 300 seconds continuously, or frequently use of the buttons will activate the overheat protection. 1) The desk will recover after 3 minutes in stand-by modus. After this standby mode, the desk should work again.
E02 2 beeps Unbalanced protection Difference between 2 columns is more than 10 min. 1) Perform reset * and operate the desk.
2) If the desk still cannot be operated normally. Then make sure the desk is cleared. After that, perform another reset.
E03 No beep, Reverses 40 mm, no matter pressing the button or not. Anti-collision Detecting the variaton of electric current column will stop when excessive variation detected in a certain time. 1) If no obstacle occurs, the desk is operational after reserving.
2) If any obstacle occurs: remove the obstacle and the desk is operational.
E04 No beep, Reverses 50 mm, no matter pressing the button or not. Sensi touch protection Detecting if the desk has collided with an object, become uneven or has shifted in angles during operation. Idem solution E03
E11 5 beeps M1 motor overcurrent protection Column M1 (motor 1) is overloaded or internal transmission is jammed. 1) Remove heavy load (if any) from desk to lower the power consumption to operate the desk.
2) If the desk still can't be operated normally, perform reset* and operate the desk.
3) If reset* can't be performed or the error keeps being triggered, column could be defected. After replacement of column M1/M2, perform reset* and operate the desk.
E12 5 beeps M2 motor overcurrent protection Column M2 (motor 2) is overloaded or internal transmission is jammed. Idem solution E11
E21 1 long beep (2 seconds) No hall sensor from M1 Only current is detected, no hall sensor. Column is not moving. 1) Perform reset* and operate the desk.
2) If reset * can't be performed or the error keeps being triggered, column could be defected. After replacement of column M1/M2, perform reset* and operate the desk.
E22 1 long beep (2 seconds) No hall sensor from M2 Only current is detected, no hall sensor. Column is not moving. Idem solution E21
E23 1 long beep (2 seconds) No hall sensor from M3 Only current is detected, no hall sensor. Column is not moving. Idem solution E21
E31 4 beeps No current from M1  No current is detected from column M1 (motor 1). One column is not moving and the other columns slightly shakes. 1) Check if the column plugs are well connected, perform a reset* and operate the desk.
2) If reset* can't be performed or the error keeps being triggered, column or control box could be defect. Now try to switch the cables connected to M1, M2 or M3 on the control box to see if the error code changes and perform solution 2a or 2b.
2a) If the error code changes, the column is defect and need to be replaced.
2b) If the error code remains the same, the control box is defect and needs to be replaced.
E32 4 beeps No current from M2 No current is detected from column M2 (motor 2). One column is not moving and the other columns slightly shakes. Idem solution E31
E33 4 beeps No current from M3 No current is detected from column M3 (motor 3). One column is not moving and the other columns slightly shakes. Idem solution E31
- No beep No current The frame does not move and the green power light on the control box does not light up. Make sure that the power plug is correctly connected to the socket.

 

FOUTMELDINGEN - Display elektrische zit-sta combinaties - WP-CB01-001

Error codes - WP-CB01-001

Reset Procedure:

Press and hold «↓» until the frame has reached the lowest position. Then press and hold «↓» for 5 seconds until you hear a beep.

Error code Cause of error Display error on handset Solution
HOT Excessive use (the frame has been actively used for two minutes) The frame stops immediately and the handset indicates HOT. Unplug the power supply, release the remaining power of the control box and plug it in again. Then wait for 20 minutes.
E02 Height difference between both legs is more than 1 cm Display shows E02  1) Perform reset* and operate the desk. .
E04 Damaged handset connection Display shows E04  Replace handset
E05 1. Anti-collision protection Display shows E05, frame rebound 50 mm.  1) Check whether the control box is installed horizontally at the bottom of the table top.
2) Check that the screws are fastened. The control box may not move.
3) Please remove the obstacle.
4) In the manual you can see how to adjust the anticollision sensitivity. Try to lower the sensitivity. Paragraph S2 explains how to do this.
E05 2. Upward current blockage  Display shows E05, frame rebound 50 mm.  1) Make sure that the control box is mounted horizontally at the bottom of the table top. The falling state triggers the E05.
2) In the manual you can see how to adjust the upward anti-collision sensitivity. This is mentioned in the manual under paragraph S3.
E05 3. Down current blockage in case of resistance Display shows E05, frame rebound 50 mm.  1) Make sure that the control box is mounted horizontally at the bottom of the table top. The falling state triggers the E05.
2) In the manual you can see how to adjust the downward anti-collision sensitivity. This is mentioned in the manual under S4.
E06 Control box issue  Display shows E06 Replace control box
E07 Power problem  Display shows E07  Unplug and replug the power supply
E11 Motor cable 1 is not connected  Display shows E11  1) Check whether the motor cable and control box interface are well connected.
2) Check whether there is obvious damage to the motor cable or check if the cable is broken.
3) If the above does not solve the problem, replace motor 1.
E13 There is a problem with motor 1 or M1 interface of control box. Displays shows E13  1) Switch the cables from the motors to a different input on the control box (switch the cables of M1 and M2 interface).
2) If the handset shows E13 as before, then there is a problem with M1 interface of the control box. Solution: replace control box.
3) If the handset shows E23, then there is a problem with the motor. Solution: replace motor.
E14 Motor 1 is not functioning Display show E14 1) Check that the cables in the motor housing are properly connected. If not, connect the cables correctly and try to operate the desk.
2) if the above does not solve the problem, replace motor 1.
E17 Motor 1 is not functioning Display show E17  1) Check that the cables in the motor housing are properly connected. If not, connect the cables correctly and try to operate the desk.
2) if the above does not solve the problem, replace motor 1.
E18 Motor 1 is overloaded  1) Reduce the load.  1) Reduce the load. 
E21 Motor cable 2 is not connect  Display shows E21  1) Check whether the motor cable and control box interface are well connected.
2) Check whether there is obvious damage to the motorcable or check if the cable is broken.
3) If the above does not solve the problem, replace motor 2.
E22 Control box issue Display shows E06  Replace control box
E24 Motor 2 is not functioning  Display show E24  1) Check that the cables in the motor housing are properly connected. If not, connect the cables correctly and try to operate the desk.
2) if the above does not solve the problem, replace motor 2..
E23 There is a problem with motor 2 or M2 interface of control box. Displays shows E23 1) Switch the cables from the motors to a different input
on the control box (switch the cables of M1 and M2
interface).
2) If the handset shows E23 as before, then there is a
problem with M2 interface of the control box. Solution:
replace control box.
3) If the handset shows E13, then there is a problem with
the motor. Solution: replace motor. 
E27 Motor 2 is not functioning Display show E27 1) Check that the cables in the motor housing are properly connected. If not, connect the cables correctly and try to operate the desk.
2) if the above does not solve the problem, replace motor 2
E28 Motor 2 is overloaded  Display shows E28 1) Reduce the load. 
E08 The two columns are unbalanced Display shows E08 1) Perform reset* and operate the desk. 
AST Reset not completely finished.  Display shows AST  1) Perform reset* and operate the desk. 
- The frame does not work at all and the handset does not show anything.  No notification on display Make sure that the power plug is correctly connected to the socket. 

 

FAQ - Frequently Asked Questions

FAQ - Frequently Asked Questions

ALGEMENE VRAGEN 

Waarom ziet u geen prijzen op de Profeq website?

  • Profeq Professional B.V. is een leverancier-groothandel in kantoormeubelen en bedrijfsinventaris. U dient eerst een account aan te maken waarbij uw bedrijfsgegevens en BTW nummer ingegeven dienen te worden. Na goedkeuring zal uw account worden vrijgegeven en kunt u alle prijzen en selectie mogelijkheden in onze website zien en eenvoudig online bestellen.

Wanneer kunt u met de ontvangst van uw bestelling rekenen?

  • Wij beschikken over een uitgebreide inhouse bezorgdienst, waardoor wij zéér stipt en correct volgens afspraak, razendsnel kunnen leveren. U wordt telefonisch of per e-mail op de hoogte gebracht van de dag en indien mogelijk het tijdstip van de levering. Wij streven ernaar binnen 5 werkdagen te leveren.

Wat zijn de verzend – leveringskosten precies?

  • Deze zijn in overleg.

Kan een bestelling ook bij mijn klant afgeleverd worden?

  • Ja, wij verzorgen ook dropshipment. Dit betekent dat u in uw account tijdens uw bestelling ook een ander afleveradres kunt ingeven. Wij leveren dan namens u, de bestelde producten op het adres van uw klant. Wij nemen namens u of de vervoerder contact op met uw klant en maken een afspraak om de bestelling te leveren. Ook hierbij gelden de bezorg en levering voorwaarden.

 

VRAGEN OVER ERGONOMIE

Wat is de EN 1335 norm?

De EN 1335 is een Europese norm voor bureaustoelen. Deze norm zegt iets over de benodigde maatvoering en instelbaarheid van een bureaustoel voor de gemiddelde European.

Wat is de EN 527 norm?

De EN 527 is een Europese norm voor bureaus, zowel zit als zit-sta bureaus met vaste hoogte of verstelbare hoogte.

Wat is de NPR 1813 norm?

De NPR 1813 is een aanvulling op de EN 1335 (EU-norm voor bureaustoelen) en de EN 527 (EU-norm voor bureaus) die richting geeft aan de maatvoering en instelbaarheid van een bureaustoel en bureau voor de gemiddelde Nederlander. Deze aanvulling op de standaard EU-norm is vanwege het feit dat de Nederlander gemiddeld groter is dan de gemiddelde Europeaan.

 

Waarin verschillen de EN 527 en de NPR 1813 voor bureaus?

Voornamelijk in maatvoering, de belangrijkste verschillen zijn:

Type bureau NEN 527 NPR 1813
Zit bureau met vaste hoogte Tussen 74 cm en 76 cm Tussen 74 cm en 76 cm
Verstelbare zit bureau Bereik van 65 cm tot 85 cm Bereik van 65 cm tot 85 cm
Verstelbare zit-sta bureau Bereik van 65 cm tot 125 cm Bereik van 65 cm tot 130 cm

 

Waarin verschillen de EN 1335 en de NPR 1813 voor bureaustoelen?

Voornamelijk in maatvoering, de belangrijkste verschillen zijn:

Bureaustoel EN 1335 NPR 1813
Zithoogte Verstelbaar tussen 40 cm en 51 cm Verstelbaar tussen 41 cm en 55 cm
Zitdiepte Verstelbaar tussen 40 cm en 42 cm Verstelbaar tussen 38 cm en 48 cm
Diepte zitting Min. 38 cm Min. 44 cm
Rugleuning Min. hoogte 22 cm Min. hoogte 37 cm
Armleggers Min. lengte 20 cm en min. 4 cm breed Min. lengte 15 cm en min. 5 cm breed